Air Cooled Chillers

When making food for human consumption, keeping your food products free from bacteria or other contaminants that could poison those who consume it is the number-one priority. A few people getting sick could ruin a food processing business, let alone if something worse happens. One of the best ways to prevent food from going bad is to control the temperature, as most bacteria cannot survive in extremely low temperatures. Water contamination can ruin a plastic product and is a very common problem. Our air-cooled screw chiller can save you dramatically by reducing product loss. Next, we’ll talk about a couple of different chilled water system configurations. Cooler shall be shell and tube design with refrigerant totally enclosed in shell and water in tubes. Exterior casing shall be manufacturer’s standard equipment casing coated with corrosion resistant exterior finish and with removable doors or panels for service and inspection. Wiring diagrams shall differentiate between manufacturer installed and field installed wiring.

This was a mint condition 2006 Trane RTAA 90 ton Air Cooled Chiller. Unit was in amazing condition and has the LOW AMBIENT option for year round outdoor use. Unit was inspected by 3rd party HVAC chiller technician prior to shipping. This unit underwent a refurbishment, including complete repainting of the chiller. The chiller contains two 15 hp Copeland compressors, a process pump, and recirculation pump. Has LOW AMBIENT controlled louvers option for year round cooling in colder climates.

injection molding chiller

While the water-cooled chiller may be more energy-efficient, it receives stiff competition from air-cooled chiller in terms of installation cost, maintenance cost, number of equipment, and several other aspects. Most importantly, air-cooled chillers avoid water consumption so they are the ideal alternatives in areas with water scarcity or areas with cheap energy but costly water fees. Give us a call today for the most specialized and customized attention. If you enjoyed this post, you maybe want to know different heat rejection condensing technologies. Air-cooled chillers are refrigeration systems used in both commercial and industrial facilities to cool fluids and/or dehumidify air. They are used in a wide variety of settings including hotels, corporate events, restaurants, sporting events, large-scale construction, industrial and manufacturing plants, and so forth.

In addition, the cooling capacity is also a factor that reflects the performance of an air-cooled chiller. Afterward, the vapor is released into the air-cooled type condenser. High efficiency, TopChiller air-cooled chiller takes a balanced approach to lower energy costs. We deliver high full-load performance to reduce demand charges and high part-load performance to reduce kWh rate charges. Understanding future air-cooled chiller performance requirements are critical to selecting the best air-cooled chiller for the project. Air-cooled chiller designed and manufactured by TopChiller has 3 or 4 refrigerant circuits for air chiller models from AC-25AF to AC-60AF depending on chiller refrigeration capacity.

Condenser coils use a V configuration to optimize heat rejection and footprint. Most Multistack modular systems comply with ASHRAE 15 and CSA B52 standards, which means you can do without auxiliary ventilation, monitoring and SCBA equipment. Not to mention an operational advantage when it comes to obtaining LEED certification. If your current chiller shows signs of aging and you are considering replacement, we are confident that you will find using our screw chillers will help you a lot with production efficiency and cost reduction. 8.2.1Adjust the cooling system flow valve carefully , to make system water flow be 90% water flow required by the nameplate on the unit. 1)Air-cooled condenser of this screw chiller with upside-down M shape layout to improve space using ratio, heat exchange area of air-cooled condenser and to reduce the unit overall size. 2)High automatic management with complete features to realize unit start-up and shut down, timing control, water pump control, malfunction alarm and self-diagnosis features. 2)A brand condensing axial fan is used in the screw chiller unit. Air-cooled screw chiller having integrity structure saves the cooling tower and reduces construction investment. Therefore, the initial pouring temperature of the concrete should be low, reaching the limit temperature of the building design unit, thus ensuring the quality of the project.

The refrigerant vapor will go back to the compressor again for the next cycle. As there is no need to install a complicated water cooling system and it’s easy to install and highly efficient, air-cooled screw chillers are more environmentally friendly compared to other kinds of chillers. Air-cooled screw chiller does not need to combine a cooling tower, easy to install, convenient to move, suitable for the occasion of lack of water source. Besides the standard air-cooled screw chiller control temperature of 7℃ to 30℃, TopChiller also has air-cooled glycol screw chiller control temperature below zero from 0℃ to -30℃. Dunham-Bush is one of the biggest commercial air conditioning companies with a global network of sales and service offices. The brand has long been committed to offering clean and green heating and cooling systems to meet the specific air-conditioning needs of the customers. From these opportunities we cautiously cherry-pick the very best new surplus and used chillers, cooling towers, rooftop units, air handlers, and HVAC equipment. The rejected items are sent on to other associates to be scrapped. Chillers play a vital role in chilled water air-conditioning system as they serve the chilled water to create the required cooling effect in the space. They produce chilled water or refrigerant which is transported by pumps and pipes to the cooling coils of conditioning units.

Arrived at KIG in January 2017 was this never used surplus Dual circuit 6 ton Riedel Air Cooled Chiller. Unit is 460 volt and a customer dual circuit design for laser machine. This one is intended for IPG lasers models YLS 4000 thru YLS 7000. It has two tanks, two pumps, and two Danfoss compressors Model MTZ-36. Okay for other lasers too, but a bit specialized for non-laser applications. In the condenser of the chiller, the heat is transferred to the condenser water, or directly to the outside air (we’ll talk more about this below). Even though chilled water systems are a new idea to most people, the concept has actually been around since the time of the ancient Romans. In order to cool their buildings, the Romans would run water through the walls to cool the space inside. But that doesn’t mean that the inside of buildings needs to be hot. While the temperature outside can sometimes be over 100 °F, the temperature inside the building can be a comfortable 74 °F.

Condenser coils appear to be in good condition with no evidence of leaks. Plate and frame evaporator has good insulation with no evidence of leaks. Here we have a 2003, 60 ton Carrier HL series chiller which has never been used or connected to power. This is a split system, meaning the chiller is indoors and the remote condenser is mounted outdoors, with field installed refrigerant lines connecting the two. You will get the 0 hours chiller, and a BRAND NEW and compatible 2013, 60 ton dual circuit condenser. Made in 2010, this is a highly engineered nice outdoor rated chiller unit for process or comfort cooling and with low ambient capability for year round operation in colder climates . Arrived at KIG in January 2016 was this substantial Trane Chilled Water Air Handler System. This was used in conjunction with a 30 ton Chiller in a climate cooling environment.

From the direct contact, the condenser water loses heat to the air. The condenser water goes back to the condenser the cycle continues. These open-topped devices come in many designs depending on many factors. Examples are cross flow, counter flow, natural draft and mechanical draft. This is a good way of settling the cooling tower vs. chiller confusion. However, if you still need more details about the water-cooled chiller components and operation, reach out to our team and you will get help. The device releases the water at about 6°C (42.8°F) and pushes it throughout the facility with the help of a pump. A network of pipes passes the chilled water through every necessary section of the building.

For the scroll compressor in small cooling capacity air cooled chiller model, TopChiller using Copeland from the USA, Danfoss from France, and Panasonic/Sanyo from Japan. The cooling capacity is the main guideline for the choice of the chiller. Equally crucial is the balance between operating costs and capital costs. However, a value-based option c onsiders both operational cost and initial cost. To determine the initial cost of each option, add the costs for both contractors and equipment. When it comes to life cycle cost, you have to consider both purchase cost and operating cost. When you evaluate each of the two chillers this way, you are able to determine its total cost. What you must note is that water-cooled chillers normally appear more valuable if you ignore first cost and water cost. However, it is only after you look at the broader coststhat the true picture appears clearly.

If you are having heating and air installation in Loganville GA, this type of environmental temperature maintenance is the most common in offices, homes, and retail outlets. Optimization of the overall chiller plant must be performed holistically. Various adjustments focusing on optimal chilled water set points, chiller sequencing and load balancing, peak demand management, cooling tower water management, etc. can only be performed with operational data. IoT has found practical application in HVAC to facilitate true optimization. Thermal Care is a leading manufacturer of water chillers, process cooling equipment and systems for applications worldwide. The cooling capacity of our premium air cooled screw chillers ranges from 30 Ton to 550 Ton and their operating sound levels are very low in all conditions. If your air cooled screw chiller gets out of order, it might result in a critical decrease in cooling capacity and even economic damages. By employing a semi-hermetic dual screw compressor, TopChiller® air cooled screw chillers are energy-efficient and able to regulate energy performance levels from 0% to 100% for maximum electricity savings. The air cooled screw chiller has protections of high/low pressure, anti-freeze, oil temperature, overload, phase sequence, and water lacking to ensure unit run safety.